Document Type : Original Article

Authors

1 Pediatric Cardiovascular Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran

2 Trauma and Injury Research Center, Iran University of Medical Sciences, Tehran, Iran

Abstract

BACKGROUND: Balloon Pulmonary Valvuloplasty (BPV) is a procedure for Pulmonary Stenosis (PS) treatment. In this study, right ventricle (RV) performance was determined through 2D-Speckle Tracking Echocardiography (2D-STE).
METHODS: The study involved 25 diagnosed children with PS undergoing BPV and 25 normal children. They were examined using 2D-STE and Linear Mixed Model (LMM) approach was used to determine changes in Pulmonary Valve Peak Gradient (PVPG), Tricuspid Annular Plane Systolic Excursion (TAPSE), strain and Strain Rate (SR) for RV, and Ejection Fraction for Left Ventricle (LVEF).
RESULTS: Notable differences were found between two groups in TAPSE (P=0.001), global strain (P=0.001), apical septal strain (P=0.024), middle septal strain (P=0.001), basal septal strain (P=0.001), apical lateral SR (P=0.001), middle lateral SR (P=0.007), basal lateral SR (P=0.001), and apical septal SR (P=0.001). Post-BPV, there was an increase in LVEF (P=0.001) and TAPSE (P=0.001) but PVPG decreased (P=0.001). Following BPV, an increase was observed in apical lateral strain (P=0.004), middle septal strain (P=0.001), apical septal strain (P=0.003), middle septal strain (P=0.001), basal septal strain (P=0.048), apical septal SR (P=0.025), and middle septal SR (P=0.023). Gender was remarkably correlated with mean changes in basal lateral strain (P=0.019), middle septal strain (P=0.037), and middle septal SR (P=0.020). Age of PS children was related to mean change in basal septal strain (P=0.031) and basal septal SR (P=0.018).
CONCLUSION: Strain and SR in RV improved post-BPV in children with PS. The gender and age of the children revealed remarkable effects on RV strain and SR changes after BPV.

1.    van der Linde D, Konings EE, Slager MA, Witsenburg M, Helbing WA, Takkenberg JJ, et al. Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis. J Am Coll Cardiol. 2011 Nov 15;58(21):2241-7. https://doi.org/10.1016/j.jacc.2011.08.025
2.    Nikyar B, Sedehi M, Mirfazeli A, Qorbani M, Golalipour MJ. Prevalence and Pattern of Congenital Heart Disease among Neonates in Gorgan, Northern Iran (2007-2008). Iran J Pediatr. 2011 Sep;21(3):307-12.  
3.    Voet A, Rega F, Van de Bruaene A, Troost E, Gewillig M, Van Damme S, et al. Long-term outcome after treatment of isolated pulmonary valve stenosis. Int J Cardiol. 2012;156(1):11-5. https://doi.org/10.1016/j.ijcard.2010.10.038 
4.    Zoghbi WA, Enriquez-Sarano M, Foster E, Grayburn PA, Kraft CD, Levine RA, et al. American Society of Echocardiography. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr. 2003 Jul;16(7):777-802. https://doi.org/10.1016/S0894-7317(03)00335-3 
5.    Lanjewar C, Phadke M, Singh A, Sabnis G, Jare M, Kerkar P. Percutaneous balloon valvuloplasty with Inoue balloon catheter technique for pulmonary valve stenosis in adolescents and adults. Indian Heart J. 2017 Mar-Apr;69(2):176-81. https://doi.org/10.1016/j.ihj.2016.11.316 
6.    Kan JS, White RI Jr, Mitchell SE, Gardner TJ. Percutaneous balloon valvuloplasty: a new method for treating congenital pulmonary-valve stenosis. N Engl J Med. 1982 Aug 26;307(9):540-2. https://doi.org/10.1056/NEJM198208263070907 
7.    Ghaderian M, Meraji M, Arabi Moghadam M-Y, Keikha M. Pulmonary regurgitation after balloon valvuloplasty in children with pulmonary stenosis. Tehran Univ Med J. 2014;72(5):307-13. 
8.    Ahmadi A, Sabri M. Percutaneous balloon valvuloplasty inpatients with pulmonary valve stenosis: a single center experiment. J Pak Med Assoc. 2012 Mar;62(3 Suppl 2):S58-61. 
9.    Pirat B, Khoury DS, Hartley CJ, Tiller L, Rao L, Schulz DG, et al. A novel feature-tracking echocardiographic method for the quantitation of regional myocardial function: validation in an animal model of ischemia-reperfusion. J Am Coll Cardiol. 2008;51(6):651-9. https://doi.org/10.1016/j.jacc.2007.10.029 
10.    Leitman M, Lysyansky P, Sidenko S, Shir V, Peleg E, Binenbaum M, et al. Two-dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr. 2004 Oct;17(10):1021-9. https://doi.org/10.1016/j.echo.2004.06.019 
11.    Mor-Avi V, Lang RM, Badano LP, Belohlavek M, Cardim NM, Derumeaux G, et al. Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography. Eur J Echocardiogr. 2011 Mar;12(3):167-205. https://doi.org/10.1093/ejechocard/jer021
12.    Song Z-Z. Global longitudinal strain by two-dimensional speckle tracking echocardiography is closely related to myocardial infarct size in chronic ischaemic heart disease. Clin Sci (Lond). 2007 Nov;113(9):393; author reply 394-5. https://doi.org/10.1042/CS20070171 
13.    Cengiz B, Şahin ŞT, Yurdakul S, Kahraman S, Bozkurt A, Aytekin S. Subclinical left ventricular systolic dysfunction in patients with severe aortic stenosis: A speckle-tracking echocardiography study. Turk Kardiyol Dern Ars. 2018 Jan;46(1):18-24. https://doi.org/10.5543/tkda.2017.43037 
14.    Chowdhury SM, Hijazi ZM, Rhodes JF, Kar S, Makkar R, Mullen M, et al. Changes in speckle tracking echocardiography measures of ventricular function after percutaneous implantation of the Edwards SAPIEN transcatheter heart valve in the pulmonary position. Echocardiography. 2015 Mar;32(3):461-9. https://doi.org/10.1111/echo.12700 
15.    Mansour A, Elfiky AA, Mohamed AS, Ezzeldin DA. Mechanism of the right ventricular reverse remodeling after balloon pulmonary valvuloplasty in patients with congenital pulmonary stenosis: A three-dimensional echocardiographic study. Ann Pediatr Cardiol. 2020 Apr-Jun;13(2):123-9. https://doi.org/10.4103/apc.APC_93_18 
16.    Alyan O, Ozdemir O, Kacmaz F, Topaloglu S, Ozbakir C, Gozu A, et al.  Sympathetic overactivity in patients with pulmonary stenosis and improvement after percutaneous balloon valvuloplasty. Ann Noninvasive Electrocardiol. 2008 Jul;13(3):257-65. https://doi.org/10.1111/j.1542-474X.2008.00229.x 
17.    Tsugu T, Murata M, Kawakami T, Minakata Y, Kanazawa H, Kataoka M, et al.  Changes in Right Ventricular Dysfunction After Balloon Pulmonary Angioplasty in Patients With Chronic Thromboembolic Pulmonary Hypertension. Am J Cardiol. 2016 Oct 1;118(7):1081-7. https://doi.org/10.1016/j.amjcard.2016.07.016 
18.    Sutherland GR, Di Salvo G, Claus P, D’hooge J, Bijnens B. Strain and strain rate imaging: a new clinical approach to quantifying regional myocardial function. J Am Soc Echocardiogr. 2004 Jul;17(7):788-802. https://doi.org/10.1016/j.echo.2004.03.027 
19.    Urheim S, Edvardsen T, Torp H, Angelsen B, Smiseth OA. Myocardial strain by Doppler echocardiography. Validation of a new method to quantify regional myocardial function. Circulation. 2000 Sep 5;102(10):1158-64. https://doi.org/10.1161/01.CIR.102.10.1158 
20.    Mahfouz RA, Moustafa TM, Gouda M, Gad M. Longitudinal function and ventricular dyssynchrony are restored in children with pulmonary stenosis after percutaneous balloon pulmonary valvuloplasty. Int J Cardiovasc Imaging. 2017 Apr;33(4):533-8. https://doi.org/10.1007/s10554-016-1036-4 
21.    Fukui S, Ogo T, Morita Y, Tsuji A, Tateishi E, Ozaki K, et al. Right ventricular reverse remodelling after balloon pulmonary angioplasty. Eur Respir J. 2014 May;43(5):1394-402. https://doi.org/10.1183/09031936.00012914 
22.    Agha H, El-Saeidi S, Abou Seif H, Abd El-Salam M, El Amrousy D. Right Ventricular Growth and Function After Balloon Valvuloplasty for Critical Pulmonary Valve Stenosis in Infants and Neonates. Pediatr Cardiol. 2020 Apr;41(4):795-800. https://doi.org/10.1007/s00246-020-02314-1